Resultados 1 - 20 de 96
Filtrar
1.
Odontology ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37938400

RESUMO

This in vitro study assessed peak temperature and temperature increase (ΔT) within the pulp chamber during different extended photoactivation techniques (EPT-applying similar radiant exposure values) to resin-based composites (RBCs) placed in a Class I cavity preparation in an extracted human lower third molar. A T-type thermocouple was placed in the pulp chamber and connected to a temperature analysis device (Thermes, Physitemp). The tooth was attached to an assembly simulating the in vivo environment (controlled baseline pulp chamber temperature and fluid flow). The real-time pulp chamber temperature was evaluated throughout the photoactivation (Bluephase N, Ivoclar Vivadent) of two bulk-fill RBCs: Tetric N Ceram Bulk Fill (TBF; shade: IVA; Ivoclar Vivadent); Surefill SDR flow + (SDR, shade: Universal; Dentsply Sirona), which were exposed to different curing techniques: 40 s-occlusal surface; 20 s-occlusal + 10 s-buccal + 10 s-lingual surfaces; 10 s-buccal + 10 s + lingual + 20 s-occlusal surfaces. Each EPT delivered 42.4 J/cm2. Vickers hardness (VHN) was measured on the removed, sectioned RBC restorations at the top and bottom middle areas after curing. ΔT and VHN data were analyzed using 2-way ANOVA followed by Bonferroni post-hoc test (α = 0.05). Peak temperature data were analyzed using one-way ANOVA and Dunnett's post-hoc test (α = 0.05). SDR showed higher ΔT values than TBF (p = 0.008) in some EPTs. Neither technique resulted in ΔT values greater than 5.5 °C. Both composites had acceptable bottom/top hardness ratios (greater than 80%), regardless of the photoactivation technique. The evaluated EPTs may be considered safe as a low-temperature increase was noticed within the pulp chamber.

2.
J Esthet Restor Dent ; 35(6): 968-979, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37560968

RESUMO

OBJECTIVE: To evaluate the accuracy of five brands of radiometers in reporting the irradiance (mW/cm2 ) from twelve brands of LCUs compared to a 'Gold Standard' (GS) reference obtained from a hand-held laboratory-grade radiometer. MATERIALS AND METHODS: The irradiance was measured from two examples of twelve brands of previously used LCUs on two examples of five brands of dental radiometers. The emission spectrum was also obtained. Irradiance data from each brand of LCU against each meter was analyzed using the Shapiro-Wilk test for normality. The irradiance values were subjected to a two-way ANOVA followed by Bonferroni tests for each LCU brand. Finally, a descriptive analysis was made using a 95% confidence interval around the mean irradiance. RESULTS: The power output from the LCUs ranged from 271 mW to 1005 mW. Among the tested radiometers, only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. When measured using the "GS" system, the mean irradiance values from the two examples of nine brands of previously used LCU were not always within ±10% of the irradiance values stated by the manufacturer. CONCLUSIONS: The mean irradiance values from 9 of the 12 brands of used LCUs were beyond ±10% of the irradiance values stated by the manufacturer. Only the Bluephase Meter II could accurately report the irradiance from 11 out of the 12 brands of LCU evaluated in this study. CLINICAL SIGNIFICANCE: There was a wide range in the power output from the LCUs tested. It was impossible to accurately measure the irradiance from all the LCUs using the dental radiometers examined. However, dental radiometers should still be used in dental offices to monitor the light output from LCUs and verify that they are working correctly before they are used on patients.


Assuntos
Resinas Compostas , Luzes de Cura Dentária , Humanos , Cura Luminosa de Adesivos Dentários , Radiometria , Teste de Materiais
3.
J Esthet Restor Dent ; 35(4): 705-716, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36738181

RESUMO

OBJECTIVE: To evaluate the in vitro pulpal temperature rise (ΔT) within the pulp chamber when low- and high-viscosity bulk-fill resin composites are photo-cured using laser or contemporary light curing units (LCUs). MATERIALS AND METHODS: The light output from five LCUs was measured. Non-retentive Class I and V cavities were prepared in one upper molar. Two T-type thermocouples were inserted into the pulp chamber. After the PT values reached 32°C under simulated pulp flow (0.026 mL/min), both cavities were restored with: Filtek One Bulk Fill (3 M), Filtek Bulk Fill Flow (3 M), Tetric PowerFill (Ivoclar Vivadent), or Tetric PowerFlow (Ivoclar Vivadent). The tooth was exposed as follows: Monet Laser (1 and 3 s), PowerCure (3 and 20 s), PinkWave (3 and 20 s), Valo X (5 and 20 s) and SmartLite Pro (20 s). The ΔT data were subjected to one-way ANOVA followed by Scheffe's post hoc test. RESULTS: Monet 1 s (1.9 J) and PinkWave 20 s (30.1 J) delivered the least and the highest amount of energy, respectively. Valo X and PinkWave used for 20 s produced the highest ΔT values (3.4-4.1°C). Monet 1 s, PinkWave 3 s, PowerCure 3 s (except FB-Flow) and Monet 3 s for FB-One and TP-Fill produced the lowest ΔT values (0.9-1.7°C). No significant differences were found among composites. CONCLUSIONS: Short 1- to 3-s exposures produced acceptable temperature rises, regardless of the composite. CLINICAL SIGNIFICANCE: The energy delivered to the tooth by the LCUs affects the temperature rise inside the pulp. The short 1-3 s exposure times used in this study delivered the least amount of energy and produced a lower temperature rise. However, the RBC may not have received sufficient energy to be adequately photo-cured.


Assuntos
Luzes de Cura Dentária , Cárie Dentária , Humanos , Temperatura , Cura Luminosa de Adesivos Dentários , Resinas Compostas , Materiais Dentários , Teste de Materiais , Polimerização
4.
Odontology ; 111(2): 387-400, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36184680

RESUMO

The temperature and Vickers Hardness (VH) at the top and bottom surfaces of three resin-based composites (RBCs) were measured when light-cured using five light-curing units (LCUs). The spectrum, power, and energy delivered to the top of the RBCs and transmitted through the RBCs were measured. Starting at 32℃, the temperature rise produced by the Monet Laser (ML-1 s and 3 s), Valo Grand (VG-3 s and 10 s), DeepCure (DC-10 s), PowerCure, (PC-3 s and 10 s) and PinkWave (PW-10 s) were measured at the bottom of specimens 2 mm deep × 6 mm wide made of Filtek Universal A2, Tetric Evoceram A2 and an experimental RBC codenamed Transcend UB. The VH values measured at the top and bottom of these RBCs were analyzed using ANOVA and Scheffe's post hoc test (p < 0.05) to determine the effects of the LCUs on the RBCs. The transmitted power from the ML was reduced by 77.4% through 2 mm of Filtek Universal, whereas light from PW decreased by only 36.8% through Transcend. The highest temperature increases from the LCU combined with the exothermic reaction occurred for Transcend, and overall, no significant differences were detected between Filtek Universal and Tetric Evoceram (p = 0.9756). Transcend achieved the highest VH values at the top and bottom surfaces. The PinkWave used for 10 s produced the largest temperature increase (20.2℃) in Transcend. The Monet used for 1 s produced the smallest increase (7.8℃) and the lowest bottom:top VH ratios.


Assuntos
Luzes de Cura Dentária , Cura Luminosa de Adesivos Dentários , Dureza , Temperatura , Teste de Materiais , Polimerização , Propriedades de Superfície , Materiais Dentários , Resinas Compostas
5.
Odontology ; 111(3): 668-679, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36534223

RESUMO

The study evaluated the pulp temperature (PT) increase in Class I and V preparations when exposed to the Monet Laser (for 1 and 3 s), the PinkWave (for 3 and 10 s), the Valo Grand (for 3 and 10 s), the PowerCure, (for 3 and 10 s) and the SmartLite Pro (for 10 s). Non-retentive Class I and Class V cavities were prepared in one molar fixed in an acrylic plate and positioned in a warm water bath. The PT baseline was kept at 32 °C to simulate physiological conditions. Two T-type thermocouples were inserted through the roots into the pulp chamber in two positions: close to the pulp horn and the buccal wall close to the Class V cavity. The water flow was adjusted to 0.026 mL/min, and real-time temperature data were collected every 0.5 s. PT measurements were made with the tip of the LCU 0 and 6 mm away from the tooth surface. The radiant exitance (mW/cm2) and radiant exposure (J/cm2) were calculated. One-way ANOVA compared the effect of the pulpal flow, and ΔT values were subjected to two-way ANOVA, followed by Scheffe's post hoc tests. The Monet Laser used for 3 s and the PinkWave used for 10 s produced the greatest PT rise in the Class I cavity. The simulated pulpal flow did not influence the PT rise. Overall, cavities exposed at the 0 mm distance had higher ΔT values than groups at 6 mm distance. The placement of a rubber dam for Class V restorations may prevent positioning LCUs directly over the cavity, which may affect the rise in PT.


Assuntos
Luzes de Cura Dentária , Cavidade Pulpar , Temperatura , Cura Luminosa de Adesivos Dentários , Lasers , Água , Resinas Compostas
6.
Materials (Basel) ; 15(17)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36079385

RESUMO

This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (µSBS) of luting agents to CAD−CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD−CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers' recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the µSBS test. Data were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The µSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest µSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in µSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD−CAM composite but also to resin cement/bonding agent/silane used.

7.
Dent Mater J ; 41(6): 874-881, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-35934800

RESUMO

Bioactive glasses have been recommended for the occlusion of dentinal tubules in treating cervical dentin hypersensitivity. This study evaluates an in vivo model of dentin exposure, and tests the efficacy of bioglass treatments. Thirty male Wistar rats received gingival recession surgery on the upper left first molar. The treatments were applied over the surface of the exposed dentin every 4 days for 28 days. The groups were as follows: Naive; Gingival recession; Cavity varnish; Biosilicate®; Strontium bioglass; and Potassium bioglass. Changes in the dentin-pulp complex, and the presence of substance P, were evaluated through hematoxylin-eosin and immunohistochemical staining. The groups had similar results. Teeth with exposed dentinal tubules in rats showed a typical pattern in the dentin-pulp complex and immunotracing for substance P. The materials did not cause pulp damage. The effects of gingival recession and open dentinal tubules on pulp tissue require further clarification.


Assuntos
Sensibilidade da Dentina , Retração Gengival , Animais , Masculino , Ratos , Dentina , Retração Gengival/cirurgia , Retração Gengival/complicações , Ratos Wistar , Substância P/farmacologia
8.
PLoS One ; 17(7): e0267359, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35802759

RESUMO

BACKGROUND: Given the increasing use of photo-activated resins in dentistry, dentists and researchers need a user-friendly dental radiometer to measure the power output from dental light-curing units (LCUs). OBJECTIVE: Our goal was to measure the accuracy of two brands of dental radiometers in reporting the power (mW) from twelve brands of contemporary LCUs compared to a 'gold standard' (GS) reference value obtained from an integrating sphere attached to a fiberoptic spectroradiometer. METHODS: The power output was measured from two units of 12 brands of LCUs, five times on the ''GS" system, five times on two Bluephase Meter II dental radiometers, and five times on two Mini Gig hand-held spectroradiometers. The emission spectrum was also recorded using the 'GS' integrating sphere. The power values reported by each meter were subjected to t-tests to compare the two examples of each LCU, and 3-way ANOVA followed by Bonferroni's post-hoc tests. Regression analyses were also performed to determine the relationship between the data from the hand-held radiometers and the 'GS' integrating sphere. RESULTS: There was a large difference in the power values (mW) and the emission spectra from the 12 brands of LCUs on their standard-settings (p<0.001). Except for one LCU (Dental Spark @ 15.1%), the differences between the two LCUs of the same brand were less than 5.3% when measured using the 'GS' integrating sphere. Regression analyses showed a highly significant agreement between the power values reported from the two brands of radiometers and the 'GS' integrating sphere (R2 > 98%). CONCLUSION: We concluded that the power values reported from both brands of dental radiometers we tested were accurate, provided that the light source did not emit wavelengths of light that were beyond the radiometer's detection limit.


Assuntos
Luzes de Cura Dentária , Cura Luminosa de Adesivos Dentários , Resinas Compostas , Teste de Materiais , Radiometria , Valores de Referência
9.
Clin Oral Investig ; 26(6): 4447-4456, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35166941

RESUMO

OBJECTIVES: To evaluate the influence of the composite resin translucency used in direct anatomic fiber posts on the bond strength (BS) and microhardness (VHN) of a luting agent into flared roots. MATERIALS AND METHODS: The root canals of 70 single-rooted premolars were endodontically treated and prepared to simulate an oversized root canal. Prior to post cementation, composite resins with varying translucency (high translucent, HT; medium translucent, MT; high opacity, HO) were placed around the fiber posts to create anatomic fiber posts. The attenuation profile (%) of light passing either through the post or through the anatomic posts (n = 8) was obtained prior to the cementing procedures. A positive control group (PC) in which a prefabricated fiber post (PFP) with the diameter compatible with the root canal was cemented and a poorly adapted fiber post (negative control group, NC) were also evaluated. For both tests, the data were subjected to 2-way ANOVA and Bonferroni tests (α = 0.05). RESULTS: A more severe light attenuation through the post at the cervical (P < .001) and medium (P < 0.001) thirds was noted when less translucent composite resin surrounded the anatomic post. HO groups showed lower BS (P = .009) and VHN (P < .001) values than the other groups, regardless of root third. No significant difference in BS values was noted between PC and HT groups. CONCLUSION: The use of a more translucent composite resin in anatomic fiber posts increased the microhardness and bond strength of a dual polymerization self-adhesive RLA compared to the use of MT and HO composite. A well-adapted PFP showed the highest adhesive and mechanical behavior. CLINICAL RELEVANCE: Clinicians should choose more translucent composite resins to create direct anatomic fiber posts to be cemented in flared root canals. That choice may allow improved mechanical properties of self-adhesive RLA and higher bond strength to the root canal as a consequence.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas/química , Colagem Dentária/métodos , Cimentos Dentários , Cavidade Pulpar , Dentina , Vidro/química , Teste de Materiais , Cimentos de Resina/química
10.
J Esthet Restor Dent ; 34(6): 951-958, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34617663

RESUMO

OBJECTIVE: The aims of this study were to evaluate whether the use of a dentifrice containing 5% potassium nitrate (KNO3 ) prior to and during in-office dental bleaching reduces bleaching-induced tooth sensitivity and affects bleaching efficiency. MATERIALS AND METHODS: Thirty-eight individuals were randomly distributed into two groups (n = 19). The experimental group performed toothbrushing using a dentifrice containing 5% KNO3 , one week before treatment and before the first and second bleaching sessions. In the control group, a placebo dentifrice without KNO3 was applied as described for the first group. Tooth sensitivity was recorded on visual analog scales (VAS) and numeric rating scales (NRS) immediately and up to 48 h after bleaching sessions. Color change at different time intervals, was evaluated with shade guide units (∆SGU) and a digital spectrophotometer (∆E CIELab 1976 and CIEDE2000) at baseline and 7, 15, and 30 days post-bleaching. Mann-Whitney test and t-test were used to evaluate TS intensity for NRS and VAS scales, respectively, and T-test was used for color difference evaluation. RESULTS: No significant difference in tooth sensitivity's absolute risk and intensity were observed between tested groups in any evaluated treatment time for NRS (p = 0.91) or VAS scales (p = 0.48). T-test showed no significant difference in both ∆E and ∆SGU tooth color among the experimental and control groups during the different evaluation times (p = 0.27). CONCLUSION: The use of a dentifrice containing 5% KNO3 does not prevent post-operatory tooth sensitivity but allows the same whitening efficiency as a regular dentifrice. CLINICAL SIGNIFICANCE: The use of a dentifrice-containing KNO3 did not prevent bleaching-induced tooth sensitivity when high-concentrated hydrogen peroxide was used for in-office bleaching.


Assuntos
Dentifrícios , Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Dentifrícios/uso terapêutico , Sensibilidade da Dentina/tratamento farmacológico , Sensibilidade da Dentina/prevenção & controle , Humanos , Peróxido de Hidrogênio/efeitos adversos , Nitratos , Compostos de Potássio/uso terapêutico , Clareamento Dental/efeitos adversos , Clareadores Dentários/efeitos adversos , Resultado do Tratamento
11.
Polymers (Basel) ; 13(7)2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33918441

RESUMO

The aim of the present study was to evaluate the influence of several experimental pretreatment crosslinker solutions on the resin polymer-dentine interface created using a representative universal adhesive system, by means of microtensile bond strength testing (µTBS), nanomechanical properties and ultramorphology confocal laser scanning microscopy (CLSM). Five experimental solutions containing different flavonoids were applied as dentine pretreatment after acid etching. A control pretreatment group containing no flavonoid was also employed. A representative modern universal adhesive was then applied, followed by a 3 mm thick composite built up. Specimens were sectioned into sticks and submitted to a µTBS test or nanoindentation analysis along the interface (24 h or 25,000 thermocycles). The ultramorphology of the polymer-resin interface was also evaluated using CLSM. The results were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). All flavonoids improved short- and long-term µTBS values (p < 0.01), while only some specific such solutions improved the nanomechanical properties (p < 0.05) and preserved the structural morphology of the interface after aging. Pretreatment of acid-etched dentine using specific flavonoid-containing solutions may be a promising approach to improve both the nanomechanical properties and the durability of modern universal adhesive systems.

12.
J Appl Oral Sci ; 29: e20200865, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33886943

RESUMO

Denture stomatitis is the most frequent oral lesion in removable prosthesis wearers, with high recurrence rates and a complex treatment. OBJECTIVE: This study describes a protocol to obtain and to contaminate a palatal device with Candida albicans biofilm that could be used for an animal model of denture stomatitis. METHODOLOGY: Acrylic resin devices (N=41) were obtained from impressions of the palates of Wistar rats with individual trays and polyether. The efficacy of microwave irradiation (MW), ultraviolet light (UV), or ultrasonic bath (US) was assessed by colony viability and spectrophotometric analyses (n=5) in order to select the most appropriate method for sterilizing the devices. Then, different devices (n=5) were contaminated with C. albicans and evaluated by CFU/mL determination, scanning electron microscopy, and laser confocal microscopy. Device stabilization was assessed with either autopolymerizing acrylic resins or a self-adhesive resin cement (n=2). The spectrophotometric data were analyzed by one-way ANOVA followed by the Tukey's HSD post-hoc test (α=0.05). RESULTS: MW was the only method capable of sterilizing the devices, and the contamination protocol developed a mature and viable C. albicans biofilm (~1.2 x 106 CFU/mL). The self-adhesive resin cement was the best stabilization material. CONCLUSIONS: This acrylic resin palatal device was designed to be similar to the clinical situation of contaminated prostheses, with easy manufacturing and handling, effective stabilization, and satisfactory contamination. Thus, the acrylic device can be a valuable tool in the development of denture stomatitis in rats.


Assuntos
Candida albicans , Estomatite sob Prótese , Resinas Acrílicas , Animais , Biofilmes , Bases de Dentadura , Palato , Ratos , Ratos Wistar
13.
Dental Press J Orthod ; 26(1): e2119150, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33729290

RESUMO

INTRODUCTION: Third generation of LED light curing units might be used in short exposure periods for orthodontic brackets bonding. OBJECTIVE: This study evaluated the effect of the different radiant exposure (RE) values: Manufacturers' instructions (MI), ½ MI, 1/4 MI and Turbo mode. Two third-generation LED curing units were used: VALO® and Bluephase 20i® . The degree of conversion (DC) and Vickers hardness (VHN) of an orthodontic composite (OC) (Transbond XT) under metallic (MB) or ceramic brackets (CB) were measured. METHODS: OC was applied to the bracket base, which was then placed over an attenuated total reflectance (ATR) table coupled to an infrared light spectroscope, or to a glass surface for the VHN analysis. The specimens were light-cured and DC values were calculated. The VHN was obtained in a microhardness tester. The data were analyzed with 2-way ANOVA followed by Tukey's post-hoc test (pre-set α=0.05). Linear regression analysis evaluated the relationship between RE values and dependent variables. RESULTS: CB allowed higher DC and VHN values than MB (p< 0.001). No significant difference was noted among groups when CB were used. For MB, MI groups showed the highest DC and VHN values. A significant, but weak relationship was found between delivered RE values and dependent variables. CONCLUSIONS: The decrease in RE values from third generation LED CU did not jeopardize the DC values when CB were used, but can compromise DC and VHN values when MB are used.


Assuntos
Luzes de Cura Dentária , Braquetes Ortodônticos , Cerâmica , Resinas Compostas , Dureza , Teste de Materiais , Polimerização , Cimentos de Resina , Propriedades de Superfície
14.
J Prosthet Dent ; 125(3): 535-542, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32204928

RESUMO

STATEMENT OF PROBLEM: Information regarding the shrinkage kinetics and monomer conversion of dual-polymerized conventional and self-adhesive resin luting agents (RLA) in situ is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the shrinkage strain and ratio of 1 conventional and 1 self-adhesive RLA by using fiber optic sensors based on Bragg gratings and Vickers hardness in the root canal. MATERIAL AND METHODS: The root canals of 34 single-rooted premolars were endodontically treated and assigned to 2 groups according to the RLA: RelyX ARC (ARC) and RelyX U200 (U200). Two Bragg grating sensors were attached to fiber posts (n=10), and both post and RLA were placed inside the root canal so that shrinkage strain and ratio values could be measured at the cervical and apical root thirds. For hardness analysis (n=7), two 1-mm-thick slices of each root-third (cervical and apical) were obtained, and 4 indentations were made on the RLA layer. The shrinkage strain and rate, as well as hardness data, were evaluated by using 2-way repeated-measures ANOVA followed by the Bonferroni post hoc test when a significant interaction between factors was detected (α=.05). RESULTS: The shrinkage strain and rate values of both RLAs were higher at the cervical third than those at the apical third. ARC showed higher shrinkage strain than U200 at the cervical third. The highest hardness values were observed at the cervical third, while ARC showed the lowest hardness values at the apical third. CONCLUSIONS: The shrinkage kinetics profile and hardness of self-adhesive RLA may differ from those of conventional RLA depending on the root third.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Cimentos Dentários , Cavidade Pulpar , Dentina , Cinética , Teste de Materiais , Polimerização , Cimentos de Resina
15.
Dental press j. orthod. (Impr.) ; 26(1): e2119150, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1154070

RESUMO

ABSTRACT Introduction: Third generation of LED light curing units might be used in short exposure periods for orthodontic brackets bonding. Objective: This study evaluated the effect of the different radiant exposure (RE) values: Manufacturers' instructions (MI), ½ MI, 1/4 MI and Turbo mode. Two third-generation LED curing units were used: VALO® and Bluephase 20i® . The degree of conversion (DC) and Vickers hardness (VHN) of an orthodontic composite (OC) (Transbond XT) under metallic (MB) or ceramic brackets (CB) were measured. Methods: OC was applied to the bracket base, which was then placed over an attenuated total reflectance (ATR) table coupled to an infrared light spectroscope, or to a glass surface for the VHN analysis. The specimens were light-cured and DC values were calculated. The VHN was obtained in a microhardness tester. The data were analyzed with 2-way ANOVA followed by Tukey's post-hoc test (pre-set α=0.05). Linear regression analysis evaluated the relationship between RE values and dependent variables. Results: CB allowed higher DC and VHN values than MB (p< 0.001). No significant difference was noted among groups when CB were used. For MB, MI groups showed the highest DC and VHN values. A significant, but weak relationship was found between delivered RE values and dependent variables. Conclusions: The decrease in RE values from third generation LED CU did not jeopardize the DC values when CB were used, but can compromise DC and VHN values when MB are used.


RESUMO Introdução: A terceira geração de LEDs fotopolimerizadores pode ser utilizada em curtos períodos de exposição para a colagem de braquetes ortodônticos. Objetivo: O presente estudo avaliou o efeito dos diferentes valores de irradiância (IR): instruções do fabricante (IF), ½ IF, » IF e modo Turbo. Dois fotopolimerizadores LED de terceira geração (VALO® e Bluephase20i®) foram utilizados. Foram mensurados o grau de conversão (GC) e a dureza Vickers (VHN) de um compósito ortodôntico (CO) (Transbond XT) sob braquetes metálicos (BM) ou cerâmicos (BC). Métodos: O compósito ortodôntico foi aplicado na base do braquete e foi posicionado sobre uma mesa de refletância total atenuada (ATR) acoplada a um espectroscópio de infravermelho ou a uma superfície de vidro para análise de VHN. As amostras foram fotopolimerizadas e os valores de GC foram calculados. O VHN foi obtido em um microdurômetro. Os dados foram analisados com ANOVA de 2 fatores seguida do teste post-hoc de Tukey (predefinido α = 0,05). A análise de regressão linear avaliou a relação entre os valores de IR e as variáveis dependentes. Resultados: BC permitiu valores maiores de GC e VHN do que BM (p<0,001). Nenhuma diferença significativa foi observada entre os grupos quando BC foi utilizado. Para BM, os grupos de IF mostraram os maiores valores de GC e VHN. Uma relação significativa, mas fraca, entre os valores de IR entregue e as variáveis dependentes foi encontrada. Conclusões: A diminuição dos valores de IR dos fotopolimerizadores LED de terceira geração não prejudicou os valores de GC quando BC foram utilizados, mas pode comprometer os valores de GC e VHN quando BM são utilizados.


Assuntos
Cerâmica , Braquetes Ortodônticos , Resinas Compostas , Luzes de Cura Dentária , Propriedades de Superfície , Teste de Materiais , Cimentos de Resina , Polimerização , Dureza
16.
J. appl. oral sci ; 29: e20200865, 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1286916

RESUMO

Abstract Denture stomatitis is the most frequent oral lesion in removable prosthesis wearers, with high recurrence rates and a complex treatment. Objective This study describes a protocol to obtain and to contaminate a palatal device with Candida albicans biofilm that could be used for an animal model of denture stomatitis. Methodology Acrylic resin devices (N=41) were obtained from impressions of the palates of Wistar rats with individual trays and polyether. The efficacy of microwave irradiation (MW), ultraviolet light (UV), or ultrasonic bath (US) was assessed by colony viability and spectrophotometric analyses (n=5) in order to select the most appropriate method for sterilizing the devices. Then, different devices (n=5) were contaminated with C. albicans and evaluated by CFU/mL determination, scanning electron microscopy, and laser confocal microscopy. Device stabilization was assessed with either autopolymerizing acrylic resins or a self-adhesive resin cement (n=2). The spectrophotometric data were analyzed by one-way ANOVA followed by the Tukey's HSD post-hoc test (α=0.05). Results MW was the only method capable of sterilizing the devices, and the contamination protocol developed a mature and viable C. albicans biofilm (~1.2 x 106 CFU/mL). The self-adhesive resin cement was the best stabilization material. Conclusions This acrylic resin palatal device was designed to be similar to the clinical situation of contaminated prostheses, with easy manufacturing and handling, effective stabilization, and satisfactory contamination. Thus, the acrylic device can be a valuable tool in the development of denture stomatitis in rats.


Assuntos
Animais , Ratos , Estomatite sob Prótese , Candida albicans , Palato , Resinas Acrílicas , Ratos Wistar , Biofilmes , Bases de Dentadura
17.
Dent Mater ; 36(9): 1151-1160, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32620332

RESUMO

OBJECTIVES: To evaluate the effect of experimental dentin pre-treatment solutions formulated with different flavonoids on microtensile bond strength (µTBS), nanohardness (NH) and ultra-morphological characteristics of artificial caries-affected dentin (CAD) bonded using a universal bonding system. METHODS: A microbiological method was used to create an artificial CAD in 91 human molars. Five experimental pre-treatment solutions were created using the following flavonoids: quercetin (QUE); hesperidin (HES); rutin (RUT); naringin (NAR), or proanthocyanidin (PRO). A placebo solution (PLA) with no flavonoids added was also evaluated. The flavonoids or placebo solutions were applied to the CAD prior to the application and photoactivation of a universal adhesive (Scotchbond Universal, 3M Oral Care). A control group (CON), in which only the bonding agent was applied without any flavonoid solution, was also evaluated. A 3-mm-thick block of resin composite (Opallis, FGM) was built up on the flat bonded CAD surfaces and was light-cured following the manufacturer's instructions. Specimens were sectioned to obtain resin-dentin slices and sticks (cross-sectional area of 0.8 mm2). The µTBS, NH, and confocal ultramorphology analysis of resin-dentin interface was evaluated at 24 h and after thermo-cycling aging (25,000 cycles). The results were analyzed using 2-way ANOVA followed by Bonferroni's post hoc test (pre-set α = 0.05). RESULTS: The specimens from groups QUE, NAR, and RUT presented greater µTBS values than those from CON group (p<0.05). Specimens from some of these experimental groups presented greater nanomechanical properties (p<0.05), and no morphological degradation at the resin-dentin interface after aging. SIGNIFICANCE: The use of exogenous cross-linkers as dentin pre-treatment before bonding procedures may represent a suitable strategy to improve the longevity of universal adhesive systems applied to caries-affected dentin.


Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Cimentos Dentários , Dentina , Flavonoides , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração
18.
Dent Mater ; 36(9): 1201-1213, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32576408

RESUMO

OBJECTIVE: To evaluate the influence of light emitted from two Polywave®, LED light-curing units (LCU) on in vivo pulp temperature (PT) rise and signs of acute inflammatory response in pulps of human premolar having deep Class V preparations. METHODS: Sixty intact, first premolars from 15 volunteers requiring extraction received infiltrative anesthesia. A sterile thermocouple probe was inserted within the pulp tissue through a minute occlusal pulp exposure in only 45 teeth (n = 9) to continuously monitor PT (°C). A deep buccal Class V preparation was created, and the surface was exposed to light from a commercial Polywave LCU (Bluephase 20i (20i), Ivoclar Vivadent) or from an experimental LCU (Exp) using the exposure modes (EM): 1s/Exp and 2s/Exp, 10s/20i, 20s/20i, and 60s/20i. Peak PT and PT rise values above baseline (ΔT) data were evaluated using a one-way ANOVA followed by Tukey's post-hoc test (α = 5%). Teeth used for histological and immunohistochemical analyses (n = 3) were extracted approximately 2 h after exposure to the LCU. RESULTS: No significant difference in peak PT and ΔT values was noted between 2s/Exp and 20s/20i groups, which both exhibited higher values than 1s/Exp and 10s/20i groups (p < 0.001). Dilated and congested blood vessels were seen after exposure to 1s/Exp, 2s/Exp, or 60s/20i EMs. The expression of IL-1ß and TNF-α tended to be more intense when higher irradiance was delivered. SIGNIFICANCE: Although higher irradiance delivered over a short exposure caused lower PT rise than 5.5 °C, such EMs should be used with caution, as they have more potential to harm the pulp tissue.


Assuntos
Luzes de Cura Dentária , Cura Luminosa de Adesivos Dentários , Dente Pré-Molar , Resinas Compostas , Polpa Dentária , Humanos , Temperatura
19.
J Prosthet Dent ; 123(1): 173-180, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31027950

RESUMO

STATEMENT OF PROBLEM: No information is available on roughness and stainability of acrylic resins polymerized by experimental microwave cycles after immersion in stainable liquids and simulated brushing. PURPOSE: The purpose of this in vitro study was to evaluate the effect of stainable drinks and brushing on roughness and stainability of acrylic resins (Vipi Cril [CA] and Vipi Wave [MA]) polymerized with different cycles. MATERIAL AND METHODS: CA and MA specimens (n=5; diameter, 20 mm; thickness, 3 mm) were made using 4 methods recommended by the manufacturer (water bath polymerization and microwave polymerization cycles) and experimental at 550 W or 650 W for 3 or 5 minutes (M550/3 and M650/5), respectively. After storage in distilled water at 37°C for 48 hours (T0), the specimens were stored in water, coffee, or red wine (37°C) for 36 days with simulated brushing (54 000 cycles, T1). Roughness (Ra) and stainability (ΔE/National Bureau of Standards) were measured at T0 and T1. Roughness and stainability data were analyzed by 3-way repeated measures and 2-way ANOVA, respectively, followed by the Bonferroni test (α=.05). RESULTS: After storing in coffee and brushing, CA showed the highest (M550/3=2.33 ±0.72 µm) and the lowest roughness (water bath polymerization=1.22 ±0.58 µm), whereas roughness of MA specimens processed by M650/5 increased (1.57 ±0.59 µm). Storing in wine and brushing increased roughness (1.75 ±0.32 µm) in the M550/3 group. No staining was observed on MA after brushing regardless of the polymerization cycle. All values were acceptable (ΔE≤3.3), except for MA (microwave polymerization), which showed National Bureau of Standards=4.49 (appreciable change) after storing in wine and brushing. CONCLUSIONS: A slight increase in material roughness was observed after staining and brushing. Only MA polymerized following manufacturer cycles showed relevant stainability after immersion in wine and brushing.


Assuntos
Resinas Acrílicas , Escovação Dentária , Teste de Materiais , Micro-Ondas , Polimerização , Propriedades de Superfície
20.
Int J Esthet Dent ; 14(4): 420-432, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31549107

RESUMO

Direct freehand veneers with composite resin (CR) require high clinician ability and a long chair time. Although CR restorations remain the most-used technique for meeting high esthetic demands, and new technologies mean that materials are nowadays more similar to tooth structure, layering techniques for natural results are still considered difficult to achieve. Through advances in adhesive dentistry, systems of prefabricated veneers using conventional techniques have been launched onto the market as an option for the clinician. This case report presents complete step-by-step descriptions of two techniques using prefabricated templates for directly built-up veneers. Both maxillary lateral incisors were simultaneously reconstructed with direct CR veneers with different layering techniques to achieve esthetic results in a shorter chair time. Simple stratification techniques using prefabricated templates may allow clinicians to optimize both time and clinical outcome while obtaining predictable results.


Assuntos
Facetas Dentárias , Estética Dentária , Resinas Compostas , Incisivo
SELEÇÃO DE REFERÊNCIAS